1SE90 Series Counterbalance Cartridge Valve, 2537-5075 PSI (Factory Setting At 3045.00), Screw with Locknut Adjustment, 4:1 Pilot Ratio

Adjustment Style
Screw with Locknut
Application
Harvesters, refuse haulers, mobile and industrial applications
Brand
Danfoss – Hydraulics
Brand
Danfoss Power Solutions
Pack Size
1.00
UOM
EA
Housing
None
Installation Type
Screw-in Cartridge
Leakage
0.25 cc/min
Maximum Load Induced Pressure
270
Maximum Relief Pressure
350
Number of Housing Ports
3
Number of Valve Ports
3
Pilot Ratio
4:1
Pressure Range (psi)
2537-5075
Pressure Setting
3045
Recommended Filtration Level
18/16/13 microns
Seal Material
Nitrile
Seal Type
Nitrile
Special Features
None
Style
Pilot assisted relief with check
Supplier Part Number
406AA00054A
Alternate Part Numbers
Alternate Part Number 1SE90F35S4, Alternate Part Number C1JZ85
Product Weight
0.92 lbs

Product Questions & Answers

Can this handle the kind of pressure you get on a refuse truck, when you're compacting stuff?
Question by: Dean S on Mar 19, 2026, 7:36 PM
Intended uses include refuse haulers. This valve has a maximum relief pressure of 5000 psi. Just be sure your system is running within that range.
Answer by: Customer Support on Mar 21, 2026, 11:20 AM
what's the pressure range on this valve and can the factory setting be adjusted if I need something different for my application?
Question by: Brett C on Feb 28, 2026, 5:45 PM
Factory set at 3045 PSI, the adjustment range runs from 2537 up to 5075 PSI. The screw and locknut design lets you dial it in without pulling the whole unit. Just loosen the locknut, turn the screw to where you need it, and lock it back down. Worth noting that any pressure above 3000 PSI requires a steel housing, so make sure your setup accounts for that before pushing it toward the top of the range.
Answer by: Customer Support on Mar 2, 2026, 3:27 PM
got a load that likes to run away on the way down, is this the kind of valve that’ll keep it in check if a hose lets go?
Question by: Lynn R on Feb 25, 2026, 1:55 PM
Built for load control, the 1SE90 counterbalance (overcenter) cartridge meters flow out of the actuator so the load cannot overrun the pump flow. When it’s close-coupled to the actuator, it also helps stop runaway in a hose burst situation, giving load holding and hose failure safety.
Answer by: Customer Support on Feb 27, 2026, 6:25 AM

Similar Products

Part Number Model Number Pilot Ratio Adjustment Style Pressure Range (psi) Pressure Setting Housing Seal Material Price Buy Now
406AA00054A 1SE90F35S4 4:1 Screw with Locknut 2537-5075 3045 None Nitrile