VD12A Series Salami VD12A CARRY OVER Plug

Brand
Salami Hydraulics Na Inc
Brand
Salami Hydraulics
Pack Size
1.00
UOM
EA
Supplier Part Number
795428800
Alternate Part Numbers
Alternate Part Number C1MZ91
Product Weight
0.09 lbs

Product Questions & Answers

carry over plug, what’s it actually do on the VD12A setup?
Question by: Danny S on Jun 23, 2025, 1:09 PM
A carry over plug is used to keep the power beyond flow path available so you can feed downstream valve sections while still having a tank return on port T.
Answer by: Customer Support on Jun 25, 2025, 6:21 AM
what's the max pressure this plug handles on the work ports?
Question by: Keith R on May 1, 2025, 3:29 PM
Ports A and B are rated up to 4500 PSI, while the P port tops out at 4000 PSI. Keep in mind the outlet port T has a back pressure limit of 363 PSI, so that one needs a little more attention when you're laying out your circuit.
Answer by: Customer Support on May 3, 2025, 1:15 PM
What pressure can this carry over plug handle on ports A and B?
Question by: Phil B on Mar 17, 2026, 1:48 PM
This VD12A series carry over plug is rated up to 4500 PSI on ports A and B.
Answer by: Customer Support on Mar 18, 2026, 6:18 PM