got a system that runs about 32 gpm. is this valve sized for that flow or am i pushin it
Question by: Dwayne C on Sep 27, 2025, 3:29 PM
For flow, it lines up. The rated flow on this VD10A series unit is 32 GPM, so a 32 GPM circuit is right at its stated capacity.
Answer by: Customer Support on Sep 29, 2025, 6:12 AM
reckon this would work alright with standard NBR seals if the fluid temp sometimes hits 180, 185 degrees?
Question by: Floyd M on Jul 5, 2025, 11:06 AM
It's designed to handle fluid temperatures up to 185°F when using standard NBR seals, so you should be good to go.
Answer by: Customer Support on Jul 7, 2025, 8:05 AM
running this on a system that sits around 150-160 degrees most of the day, is that gonna be too hot for the seals?
Question by: Howard O on Dec 6, 2025, 4:51 PM
Standard NBR seals on this unit are rated for fluid temps up to 185°F, so a system running steady in that 150 to 160 range stays well within the safe zone. The ambient temperature rating tops out at 140°F, so keep that in mind for the environment around the valve itself, not just the fluid. As long as both of those stay within their respective limits, you should be in good shape day to day.
Answer by: Customer Support on Dec 8, 2025, 6:38 AM
i got a system that runs right around 32 gpm, is this inlet module gonna be the bottleneck?
Question by: Donna B on Jan 30, 2026, 7:49 AM
For flow, the VD10A Series inlet module is rated at 32 GPM, so it matches a 32 GPM circuit on paper. Keep in mind the published technical data was taken using mineral oil at 16 cSt and ISO 4406 contamination level 19/16, since viscosity and cleanliness can affect how a valve section behaves in real use.
Answer by: Customer Support on Jan 31, 2026, 6:21 PM
what's the fluid temperature range on this inlet module, and does it handle anything below freezing?
Question by: Lance R on Oct 28, 2025, 6:17 AM
With standard NBR seals, the fluid temperature range runs from -4°F up to 185°F. So yes, it does go below freezing, though just barely on the low end. As long as your system fluid stays within that window, you're in good shape. Keep in mind the ambient temperature rating sits between 86°F and 140°F, so the surrounding environment has its own separate limits to account for.
Answer by: Customer Support on Oct 29, 2025, 8:32 PM
What kind of fluid works best in this VD10A series valve? I'm using some pretty thick stuff now.
Question by: Warren B on Jan 18, 2026, 7:23 PM
Optimal fluid viscosity for this Salami VD10A module is between 12 cSt and 75 cSt. It can handle as low as 10 cSt and as high as 460 cSt, but that's pushing the limits.
Answer by: Customer Support on Jan 20, 2026, 1:28 PM