Series 3-6-12 Steering Control Unit, Non-Load Reaction, 29.70 cu in/rev, 8-16 GPM Flow Range, 3/4-16 St.Thd O-Ring Ports, Can be used in a variety of applications|Flow rate variability|Varying maximum pressure ratings

Additional Ports
None
Application
Agricultural Equipment, Forestry Equipment, Construction Equipment, Turf Care Equipment, Industrial Equipment
Design Code
2
Displacement
29.70
Displacement
29.7
Brand
Danfoss – Hydraulics
Brand
Danfoss Power Solutions
Pack Size
1.00
UOM
EA
Features
Can be used in a variety of applications|Flow rate variability|Varying maximum pressure ratings
Flow Amplification
None
Flow Range
8-16
Flow Rate1
45 LPM
Identification
Eaton Product Number On Nameplate
Inlet Load Sense Valve Sett
0 b
Inlet Pressure Rating
172
Input Torque
Standard
Integral Valves
Yes
Load Circuit
Non Reaction
Maximum Back Pressure
21
Mechanical Interface
Internal Involute Spline, 12 Tooth 16/32 Dp 30 Degree Pa
Mounting Threads
2X .375-24 UNF-2B Port Face 4X .375-16 UNC-2B Mounting Face
Ports
3/4-16 St.Thd O-Ring
Ports
3/4-16 St.Thd O-Ring
Recommended Filtration Level
ISO 18/13 Cleanliness
Return Pressure Rating
10
Special Features
Low Torque Shaft Seal
Supplier Part Number
211-1178-002
Valve Options
Manual Steering Check Valve
Product Weight
75.00 lbs
Alternate Part Numbers
Alternate Part Number 211-1039, Alternate Part Number 211-1178-002, Alternate Part Number C1BC22

Product Questions & Answers

got a tractor with hydro steering. what kinda flow does this steering unit want to see?
Question by: Pete H on Jan 1, 2026, 8:14 PM
For flow, it is set up for an 8 to 16 GPM range, which is also listed as 45 LPM. That keeps it in the window the unit is meant to run in for normal steering performance.
Answer by: Customer Support on Jan 3, 2026, 6:33 AM

Similar Products

Model Number Displacement Flow Range Ports Features Price Buy Now
211-1001 4.5 2-4 9/16-18 St.Thd O-Ring Can be used in a variety of applications|Flow rate variability|Varying maximum pressure ratings
211-1007 4.5 4-8 3/4-16 St.Thd O-Ring Can be used in a variety of applications|Flow rate variability|Varying maximum pressure ratings
211-1008 5.9 4-8 3/4-16 St.Thd O-Ring Can be used in a variety of applications|Flow rate variability|Varying maximum pressure ratings
211-1009 7.3 4-8 3/4-16 St.Thd O-Ring Can be used in a variety of applications|Flow rate variability|Varying maximum pressure ratings
211-1010 9.7 4-8 3/4-16 St.Thd O-Ring Can be used in a variety of applications|Flow rate variability|Varying maximum pressure ratings
211-1011 11.3 4-8 3/4-16 St.Thd O-Ring Can be used in a variety of applications|Flow rate variability|Varying maximum pressure ratings
211-1012 14.1 4-8 3/4-16 St.Thd O-Ring Can be used in a variety of applications|Flow rate variability|Varying maximum pressure ratings
211-1158 17.9 4-8 3/4-16 St.Thd O-Ring Can be used in a variety of applications|Flow rate variability|Varying maximum pressure ratings
211-1177 23.8 8-16 3/4-16 St.Thd O-Ring Can be used in a variety of applications|Flow rate variability|Varying maximum pressure ratings
211-1178 29.7 8-16 3/4-16 St.Thd O-Ring Can be used in a variety of applications|Flow rate variability|Varying maximum pressure ratings
211-1179 45.1 8-16 3/4-16 St.Thd O-Ring Can be used in a variety of applications|Flow rate variability|Varying maximum pressure ratings