J Series Geroler Motors, Up To 743 lb-in Intermittent Torque, 2458 Intermittent RPM

Fluid Viscosity

Minimum: 70 SUS at operating temperature. Recommended Range: 100-200 SUS.

Maximum Case Pressure

1100 PSI (Without case drain). For continuous back pressure over 1100 PSI, use an external case drain line. Install line so motor case remains full at all times.

Maximum Operating Temperature

180° F.

Recommended Break-In

To assure best motor life, run motor for approximately one hour at 30% of rated pressure before application to full load. Be sure motor is filled with fluid prior to any load applications.

Recommended Filtration

Per ISO Cleanliness Code, level 18/13.

Recommended Fluids

Premium quality, anti-wear type hydraulic fluid.

Seal Kit

Part number: 60580

Products