GC8000 Series Basic DC Power Unit, 12VDC Single Terminal Std Duty Motor, .250" Gear Gear Pump, 3 Quarts Reservoir

Current
At 500 PSI: 115A, At 2000 PSI, 205A
Brand
Concentric Rockford Inc
Brand
Concentric Rockford
Pack Size
1.00
UOM
EA
Features
.250'' Gear
Motor
12VDC Single Terminal Std Duty
Motor Start Switch
Case (Internal) Grounded
Oil Capacity
3 Quarts
Rated Flow at 2000 PSI
1.35
Rated Flow at 500 PSI
2.25
Relief Setting
2500
Supplier Part Number
1300757
Alternate Part Numbers
Alternate Part Number C1EL95
Product Weight
25.95 lbs

Product Questions & Answers

what's the duty cycle on this thing? running it at 2000 psi and it keeps getting hot on me
Question by: Phil R on Oct 12, 2025, 9:10 AM
At 2000 psi with the .250" gear pump, you've got about a 30-second run time per 5-minute period before it needs to cool down. At 500 psi you get a full minute before you have to let it rest. That heat buildup is normal if you're pushing past those limits, so keeping an eye on your cycle times will go a long way toward protecting the motor.
Answer by: Customer Support on Oct 13, 2025, 9:07 PM

Similar Products

Part Number Motor Motor Start Switch Rated Flow at 500 PSI Rated Flow at 2000 PSI Current Relief Setting Oil Capacity Features Price Buy Now
1300757 12VDC Single Terminal Std Duty Case (Internal) Grounded 2.25 1.35 At 500 PSI: 115A, At 2000 PSI, 205A 2500 3 Quarts .250'' Gear