GC8000 Series Manual Control DC Power Unit, 12VDC Single Terminal Std Duty Motor, .250" Gear Pump, 3 Quarts Reservoir

Current
At 500 PSI: 115A, At 2000 PSI, 205A
Brand
Concentric Rockford Inc
Brand
Concentric Rockford
Pack Size
1.00
UOM
EA
Features
.250'' Gear
Motor
12VDC Single Terminal Std Duty
Motor Start Switch
Case (Internal) Grounded
Oil Capacity
3 Quarts
Rated Flow at 2000 PSI
1.35
Rated Flow at 500 PSI
2.25
Relief Setting
2500
Supplier Part Number
1300754
Alternate Part Numbers
Alternate Part Number C1EL94, Alternate Part Number MI-08702437, Alternate Part Number MINO-04180X96542
Product Weight
27.00 lbs

Product Questions & Answers

how long can i run this motor without burning it up. pulling a pretty heavy load at 2000 psi most of the time
Question by: Freddie H on Mar 4, 2026, 8:54 PM
Running at 2000 PSI requires strict cooling breaks. Over any five minute window you can only operate the unit for thirty seconds at that pressure level before letting it cool down completely. Operating at a lower 500 PSI extends that run time to a full minute.
Answer by: Customer Support on Mar 6, 2026, 6:39 AM
got a .250 gear pump on this unit, what kinda flow are we talkin at 500 psi versus 2000?
Question by: Dustin W on Aug 20, 2025, 7:48 AM
At 500 PSI it is rated for 2.25 GPM, and at 2000 PSI it is rated for 1.35 GPM with the .250 inch gear pump.
Answer by: Customer Support on Aug 22, 2025, 6:58 AM
what's the duty cycle on this thing? got a job where it might be running pretty regular and don't want to burn it up
Question by: Jerry E on Sep 7, 2025, 8:47 PM
At 500 psi, you get about one minute of run time over any five minute stretch. Drop it to half a minute if you're pushing up near 2000 psi. After that it needs to cool down before you run it again. This is a standard duty motor, so it's built for intermittent work, not continuous operation. If your job calls for longer run cycles, you'd want to look at a heavier duty setup.
Answer by: Customer Support on Sep 9, 2025, 9:48 AM

Similar Products

Part Number Motor Motor Start Switch Rated Flow at 500 PSI Rated Flow at 2000 PSI Current Relief Setting Oil Capacity Features Price Buy Now
1300754 12VDC Single Terminal Std Duty Case (Internal) Grounded 2.25 1.35 At 500 PSI: 115A, At 2000 PSI, 205A 2500 3 Quarts .250'' Gear