Delta Series Geroler Motor, 33.10 cu in/rev, Wheel Mounting Flange, 1-1/4" Tapered Shaft, 7/8" O-Ring Ports, Standard, wheel or bearingless configurations|Lowest pressure drop motor in the industry|Highly-efficient Geroler motor provides energy savings

Application
Other: Scissor Lift, Boom Lift, Industrial Sweeper, Mower
Design Code
2
Displacement
33.10
Displacement
33.1
Brand
Danfoss Power Solutions II (Char-Lynn)
Brand
Char-Lynn
Pack Size
1.00
UOM
EA
Features
Standard, wheel or bearingless configurations|Lowest pressure drop motor in the industry|Highly-efficient Geroler motor provides energy savings
Identification
None
Mount
Wheel
Mount
Wheel
Port Type
.875-14 UNF-2B SAE O-Ring Ports
Ports
7/8" O-Ring
Ports
7/8" O-Ring
Shaft
1-1/4" Tapered
Shaft
1-1/4" Tapered
Supplier Part Number
184-0010-002
Torque Rating
994 newton metre
Torque Rating
994 newton metre
Valve Options
None
Alternate Part Numbers
Alternate Part Number 184-0010-002, Alternate Part Number C1LW81
Product Weight
36.10 lbs

Product Questions & Answers

got a wheel motor setup, how do i know if this one’s the right mount and ports?
Question by: Kurt M on Sep 13, 2025, 2:44 PM
Fit comes down to the basics on this motor: it uses a wheel mounting flange, a 1-1/4 inch tapered shaft, and 7/8 inch SAE O-ring ports with .875-14 UNF-2B threads. If those three match what you’re swapping, you’re in the right neighborhood for mounting and hook-up.
Answer by: Customer Support on Sep 15, 2025, 6:20 AM
What kind of machines would this motor be good for? I have a boom lift that needs a new motor.
Question by: Keith L on Jan 22, 2026, 3:51 PM
This Delta Series motor is used in applications like scissor lifts, boom lifts, industrial sweepers, and mowers.
Answer by: Customer Support on Jan 24, 2026, 12:54 PM
been running a scissor lift with a wore out motor and trying to figure out if this one'll hold up better, what's the torque rating on this thing?
Question by: Danny B on Jan 21, 2026, 8:38 AM
Rated at 994 newton metres of torque, this motor has plenty of muscle for scissor lift duty. The Geroler design also runs with the lowest pressure drop in its class, which means less heat buildup and more efficient use of your hydraulic system over the course of a shift. For break-in, run it at roughly 30% of rated pressure for about an hour before putting it under full load, and make sure it's filled with fluid before you ever apply any load to it.
Answer by: Customer Support on Jan 23, 2026, 6:56 AM

Similar Products

Model Number Displacement Mount Shaft Ports Features Price Buy Now
184-0010 33.1 Wheel 1-1/4" Tapered 7/8" O-Ring Standard, wheel or bearingless configurations|Lowest pressure drop motor in the industry|Highly-efficient Geroler motor provides energy savings
184-0161 18.3 Wheel 1-1/2" Straight Keyed 7/8" O-Ring Standard, wheel or bearingless configurations|Lowest pressure drop motor in the industry|Highly-efficient Geroler motor provides energy savings