flow rate on this valve is listed at 141 L/min but the series goes up to 350 L/min, does that mean this particular model is restricted to the lower rating or is that just the tested flow for this configuration?
Question by: Harold R on Sep 1, 2025, 1:17 PM
The 141 liters per minute figure is specific to this model within the FDC1-20 series. The 350 L/min rating applies to the broader series, not to every individual valve in it. This unit is sized and configured for the 141 L/min range, so plan your system around that number rather than the series maximum.
Answer by: Customer Support on Sep 2, 2025, 6:19 PM
Will this flow control valve work alright on a refuse hauler?
Question by: Freddie T on Oct 13, 2025, 5:05 PM
These Vickers flow control valves are used in mobile applications, including refuse haulers, so it should work fine for your needs.
Answer by: Customer Support on Oct 15, 2025, 11:03 AM