VICKERS-RV1A-10-I-0-18/5

Application
Harvesters, refuse haulers, mobile and industrial applications
Brand
Danfoss – Hydraulics
Brand
Vickers
Pack Size
1.00
UOM
EA
Features
350 bar (5000 psi) & 300 L/min (80 USgpm)|Reliable, economical and compact|Maximum flexibility and minimum space
Flow Rate1
30 litre per minute
ICC
SICV Pressure Control Valves
Language
English
Port Size
None
Product Width
1
Style
Poppet
Sub Brand
Vickers
Supplier Part Number
307AA00658A
Product Weight
0.48 lbs

Product Questions & Answers

Reckon this'll hold up okay on a refuse hauler, dealin' with all that pressure?
Question by: Travis T on Sep 12, 2025, 7:56 AM
Designed for demanding applications like refuse haulers and harvesters, this Vickers pressure control valve handles up to 350 bar (5000 psi).
Answer by: Customer Support on Sep 13, 2025, 6:17 PM
Got a harvester that keeps blowing out the relief valve on the hydraulic circuit, would this Vickers RV1A-10-I-0-18/5 hold up to that kind of regular abuse?
Question by: Rod G on Mar 2, 2026, 7:05 PM
Harvesters are actually one of the listed applications for this valve, so it's built with that kind of demanding, high-stress environment in mind. Rated to 350 bar (5000 psi) and using a poppet-style design, it can handle the pressure spikes that come with that type of work. The poppet style is generally more tolerant of repeated pressure events than spool-type valves, which makes it a reasonable fit for circuits that cycle hard and often.
Answer by: Customer Support on Mar 4, 2026, 6:36 AM