VICKERS-RV3-10-I-0-6/2.8

Application
Harvesters, refuse haulers, mobile and industrial applications
Brand
Danfoss – Hydraulics
Brand
Vickers
Pack Size
1.00
UOM
EA
Features
350 bar (5000 psi) & 300 L/min (80 USgpm)|Reliable, economical and compact|Maximum flexibility and minimum space
Flow Rate1
76 litre per minute
ICC
SICV Pressure Control Valves
Language
English
Port Size
None
Product Width
1
Style
Poppet
Sub Brand
Vickers
Supplier Part Number
307AA00013A
Product Weight
0.48 lbs

Product Questions & Answers

Running a refuse hauler and been going through pressure control valves faster than I'd like. This RV3-10 rated for the kind of pressure them systems put out?
Question by: Ronnie E on Mar 9, 2026, 9:22 PM
Rated at 350 bar, which works out to 5000 psi, so yes it holds up well under the pressure loads typical of refuse hauler hydraulic circuits. The RV3-10 series was built with exactly that kind of mobile equipment work in mind, and the poppet style construction tends to hold up reliably in those high-demand cycles.
Answer by: Customer Support on Mar 11, 2026, 11:23 AM
What kind of machines would use this RV3-10 valve?
Question by: Daryl T on Aug 5, 2025, 4:25 PM
Primarily, this valve is used in harvesters and refuse haulers, along with general mobile and industrial applications. Its design is optimized for systems requiring precise pressure management.
Answer by: Customer Support on Aug 6, 2025, 9:18 PM