VICKERS FAR1-10V-S-0-2.50

Application
Harvesters, refuse haulers, mobile and industrial applications
Brand
Danfoss – Hydraulics
Brand
Vickers
Pack Size
1.00
UOM
EA
Features
350 bar (5000 psi) & 350 L/min (92 USgpm)|Perfect balance of pressure and flow|Reliable, economical and compact
Flow Rate1
38 litre per minute
ICC
SICV Flow Control Valves
Language
English
Product Width
1
Style
Pressure Compensated with Free Reverse Flow
Sub Brand
Vickers
Supplier Part Number
305AA00182A
Product Weight
0.44 lbs

Product Questions & Answers

flow rate on this one says 38 liters per minute but the specs also mention 350 L/min capacity -- which number actually applies to my setup?
Question by: Hank P on Apr 24, 2025, 7:54 PM
Both numbers are real, they just describe different things. The 350 L/min figure is the maximum flow capacity the valve is rated to handle through the system. The 38 L/min is the controlled flow rate this valve is set to deliver. So if you're running a circuit that needs a steady, regulated flow output, 38 L/min is what you're working with on the controlled side.
Answer by: Customer Support on Apr 26, 2025, 7:28 AM
If I'm dealing with pressures around 4800 psi, will this valve hold up okay?
Question by: Roger T on Apr 26, 2025, 4:45 PM
This Vickers flow control valve is rated to handle pressures up to 5000 psi (350 bar), so you should be good to go in that range.
Answer by: Customer Support on Apr 28, 2025, 6:54 AM