VICKERS PFR5-10-F-0-1.40

Application
Harvesters, refuse haulers, mobile and industrial applications
Brand
Danfoss – Hydraulics
Brand
Vickers
Pack Size
1.00
UOM
EA
Features
350 bar (5000 psi) & 350 L/min (92 USgpm)|Perfect balance of pressure and flow|Reliable, economical and compact
Flow Rate1
23 litre per minute
ICC
SICV Flow Control Valves
Language
English
Product Width
1
Style
Fixed Pressure Compensated, Flow Regulator
Sub Brand
Vickers
Supplier Part Number
305AA00092A
Product Weight
0.28 lbs

Product Questions & Answers

Got a refuse hauler that keeps surging under variable load conditions, would a fixed pressure-compensated valve like this one help keep the flow steady?
Question by: Roy B on Jan 17, 2026, 11:07 AM
Fixed pressure compensation is exactly what addresses that kind of surging. The PFR5-10-F-0-1.40 holds its output at 23 litres per minute regardless of load-induced pressure swings, so the downstream circuit sees consistent flow even when system pressure is bouncing around. For refuse haulers specifically, this valve is a recognized fit, it's listed as a target application. Rated to 350 bar, it's also got the pressure tolerance to handle the demands that type of equipment puts on a hydraulic circuit.
Answer by: Customer Support on Jan 19, 2026, 6:30 AM