VICKERS FR5-10-F-0-.30

Application
harvesters, refuse haulers, mobile and industrial applications
Brand
Danfoss – Hydraulics
Brand
Vickers
Pack Size
1.00
UOM
EA
Features
350 bar (5000 psi) & 350 L/min (92 USgpm)|Perfect balance of pressure and flow|Reliable, economical and compact
Flow Rate1
23 litre per minute
ICC
SICV Flow Control Valves
Language
English
Product Width
1
Style
Fixed Pressure Compensated, Flow Regulator
Sub Brand
Vickers
Supplier Part Number
305AA00002A
Product Weight
0.26 lbs

Product Questions & Answers

Running this on a refuse hauler and just want to make sure I got the right part before I pull the old one out. This a fixed flow setup or can you adjust it?
Question by: Terry B on Oct 10, 2025, 7:02 AM
Fixed pressure compensated is exactly what this is. The flow output stays steady at 23 litres per minute regardless of pressure swings up or downstream, so there's no adjustment dial or variable setting to mess with. That's actually what makes it well suited for refuse haulers where your load conditions shift constantly but you still need consistent flow. If 23 LPM is what your system calls for, this should drop right in where the old one came out.
Answer by: Customer Support on Oct 11, 2025, 6:36 PM
Will this Vickers valve hold up okay on a refuse truck, since they cycle a lot?
Question by: Cindy W on Feb 1, 2026, 8:47 PM
Designed for demanding mobile hydraulic systems like refuse haulers, this flow regulator maintains stable performance even with frequent load shifts. Its fixed pressure compensation helps ensure consistent flow output.
Answer by: Customer Support on Feb 3, 2026, 6:57 AM