2000 Series Geroler Motors, Up to 8225 lb-in Intermittent Torque, 1042 Intermittent RPM

Fluid Viscosity

Minimum: 70 SUS at operating temperature. Recommended Range: 100-200 SUS.

Maximum Case Pressure

2000 PSI (Without case drain). For continuous back pressure over 2000 PSI, use an external case drain line. Install line so motor case remains full at all times.

Maximum Operating Temperature

180° F.

Recommended Break-In

To assure best motor life, run motor for approximately one hour at 30% of rated pressure before application to full load. Be sure motor is filled with fluid prior to any load applications.

Recommended Filtration

Per ISO Cleanliness Code, level 18/13.

Recommended Fluids

Premium quality, anti-wear type hydraulic fluid.