2-Section Geared Flow Divider, 1.46 cu in/rev, 3/4 NPTF Inlet, 3/4 NPTF Outlet, 6.40 To 44.00 Inlet Flow Range

Displacement
1.46
Displacement
1.462
Brand
Delta Power Co
Brand
Delta Power Co
Pack Size
1.00
UOM
EA
Inlet Port
3/4 NPTF
Max. Diff. Pressure Between Sections
1000
Maximum Operating Pressure
1500
Outlet Port
3/4 NPTF
Recommended Maximum Inlet Flow
44
Recommended Minimum Inlet Flow
6.40
Alternate Part Numbers
Alternate Part Number C1DG34
Supplier Part Number
30500027
Product Weight
21.00 lbs

Product Questions & Answers

got two cylinders i need to move together off one pump. is this the kind of flow divider that keeps em in sync?
Question by: Lyle M on Apr 25, 2025, 11:51 AM
Built for splitting one pump flow into two equal, proportional flows, it is commonly used to synchronize two hydraulic cylinders. It is a 2 section geared divider, so each section shares the inlet and helps keep the two outlet flows matched.
Answer by: Customer Support on Apr 27, 2025, 6:52 AM

Similar Products

Model Number Displacement Inlet Port Outlet Port Recommended Minimum Inlet Flow Recommended Maximum Inlet Flow Max. Diff. Pressure Between Sections Maximum Operating Pressure Maximum Intermittent Pressure Price Buy Now
P23 0.702 3/4 NPTF 1/2 NPTF 1000 1500
P27 1.462 3/4 NPTF 3/4 NPTF 1000 1500