2-Section Geared Flow Divider, 0.70 cu in/rev, 3/4 NPTF Inlet, 1/2 NPTF Outlet, 3.00 To 21.00 Inlet Flow Range

Displacement
0.70
Displacement
0.702
Brand
HYDRAULIC TECH USA LLC(SPX)
Brand
Hydraulic Tech USA
Pack Size
1.00
UOM
EA
Inlet Port
3/4 NPTF
Max. Diff. Pressure Between Sections
1000
Maximum Operating Pressure
1500
Outlet Port
1/2 NPTF
Recommended Maximum Inlet Flow
21
Recommended Minimum Inlet Flow
3
Alternate Part Numbers
Alternate Part Number C1DG32, Alternate Part Number C1KN91
Supplier Part Number
P23
Product Weight
15.80 lbs

Product Questions & Answers

Got two cylinders I'm trying to keep in sync and they keep drifting on me. Would a flow divider like this fix that, or am I barking up the wrong tree?
Question by: Gene D on Jul 22, 2025, 5:28 PM
Equal flow from a single pump source is exactly what this unit is built for. It splits incoming flow into two separate streams at equal proportion, which is what keeps paired cylinders moving together instead of one running ahead of the other. Worth noting that you'll get the best accuracy when you're running it close to the maximum rated inlet flow of 21 GPM rather than down at the low end of the 3 to 21 GPM range. Also make sure you have relief valves protecting each circuit and run a 25-micron filter on it. Those two things make a real difference in how well it holds sync over time.
Answer by: Customer Support on Jul 24, 2025, 6:41 AM

Similar Products

Model Number Displacement Inlet Port Outlet Port Recommended Minimum Inlet Flow Recommended Maximum Inlet Flow Max. Diff. Pressure Between Sections Maximum Operating Pressure Maximum Intermittent Pressure Price Buy Now
P23 0.702 3/4 NPTF 1/2 NPTF 1000 1500
P27 1.462 3/4 NPTF 3/4 NPTF 1000 1500