1SEB90 Series Counterbalance Cartridge Valve, 1088-5076 PSI (Factory Setting At 3046.00), Screw Adjustment, 4:1 Pilot Ratio

Adjustable Range
1088-5076
Adjustment Style
Screw
Application
Harvesters, refuse haulers, mobile and industrial applications
Control Ratio
4:1
Brand
Danfoss – Hydraulics
Brand
Danfoss Power Solutions
Pack Size
1.00
UOM
EA
Housing
None
Installation Type
Screw-in Cartridge
Leakage
0.25 cc/min
Maximum Load Induced Pressure
270
Maximum Relief Pressure
350
Number of Housing Ports
3
Number of Valve Ports
3
Preset Pressure
3046
Recommended Filtration Level
18/16/13 microns
Seal Material
Nitrile
Seal Type
Nitrile
Special Features
None
Style
Pilot assisted relief with check
Supplier Part Number
406AA00056A
Alternate Part Numbers
Alternate Part Number 1SEB90F35S4, Alternate Part Number C1LX28
Product Weight
0.92 lbs

Product Questions & Answers

got a refuse hauler that keeps creeping under load, would a 4:1 pilot ratio valve like this one be the right call or do i need something different
Question by: Daryl R on Jun 12, 2025, 7:36 AM
For loads that stay pretty consistent, the 4:1 pilot ratio on this valve is actually the recommended choice. It's built specifically for applications where load pressure doesn't swing around much, and refuse haulers fall right into that category. The valve works by requiring pilot pressure to overcome spring force reduced by load pressure, so you get a gradual, controlled opening rather than a sudden dump of flow. That metered response is what keeps a loaded arm or cylinder from running away on you. Factory setting comes in at 3046 PSI but the screw adjustment lets you dial it anywhere from 1088 up to 5076 PSI to match your actual system needs.
Answer by: Customer Support on Jun 14, 2025, 6:38 AM
got a cylinder that likes to run away if a hose lets go. is this the kind of valve that’ll hold the load and keep it from free-falling?
Question by: Bonnie B on Feb 2, 2026, 12:50 PM
Built for load control, the 1SEB90 counterbalance (overcenter) valve is used to control moving loads and prevent load runaway, adding load holding and hose failure safety when applied correctly in the circuit.
Answer by: Customer Support on Feb 3, 2026, 4:36 PM
So, this thing is made to screw right into something, right? Like, I don't need a whole separate housing, do I?
Question by: Steve J on Feb 9, 2026, 1:42 PM
Installation is as a screw-in cartridge. For this 1SEB90 series valve, you'll need either a machined T2A Sun cavity or a housing. The A20092-T2A or Sun T2A housing is sold separately.
Answer by: Customer Support on Feb 10, 2026, 2:26 PM

Similar Products

Part Number Model Number Control Ratio Adjustment Style Adjustable Range Preset Pressure Housing Seal Material Price Buy Now
406AA00056A 1SEB90F35S4 4:1 Screw 1088-5076 3046 None Nitrile