10000 Series Geroler Motors, Up to 30460 lb-in Intermittent Torque, 784 Intermittent RPM

Fluid Viscosity

Minimum: 70 SUS at operating temperature. Recommended Range: 100-200 SUS.-viscosity

Maximum Case Pressure

300 PSI (Without case drain). For continuous back pressure over 300 PSI, use an external case drain line. Install line so motor case remains full at all times.-case pressure

Maximum Operating Temperature

180° F.-temperature

Recommended Break-In

To assure best motor life, run motor for approximately one hour at 30% of rated pressure before application to full load. Be sure motor is filled with fluid prior to any load applications.-break in

Recommended Filtration

Per ISO Cleanliness Code, level 18/13.

Recommended Fluids

Premium quality, anti-wear type hydraulic fluid.-fluids