Got a harvester running a 12V electrical system, will this valve keep up with the flow demands on something like that?
Question by: Rusty C on Sep 3, 2025, 3:19 PM
For high-flow mobile equipment running on 12 volts, this is a solid fit. The EPV16 Series handles up to 160 L/min (42 USgpm), which covers the kind of flow demands you'd see in harvester hydraulic circuits. It's a poppet-style proportional valve, so you get consistent, controlled flow rather than on/off switching. The compact build also helps when you're working around tight mounting areas on mobile equipment.
Answer by: Customer Support on Sep 5, 2025, 11:00 AM
If I'm using this on a harvester, what kinda flow rate can I expect?
Question by: Donna H on Jul 7, 2025, 9:37 PM
Rated flows go all the way up to 160 L/min (42 USgpm), so it's suited for high-flow mobile circuits like you'd find on a harvester.
Answer by: Customer Support on Jul 9, 2025, 9:07 PM