VICKERS CV11-10-P-0-55

Application
Harvesters, refuse haulers, mobile and industrial applications
Brand
Danfoss – Hydraulics
Brand
Vickers
Pack Size
1.00
UOM
EA
Features
350 bar (5000 psi) & 227 L/min (60 USgpm)|High operational efficiency|Low spring settings
Flow Rate1
114 litre per minute
ICC
SICV Check Valves
Language
English
Product Width
1
Style
Poppet
Sub Brand
Vickers
Supplier Part Number
02-200406
Product Weight
0.17 lbs

Product Questions & Answers

Running a refuse hauler and need a check valve that can keep up with high-pressure demand. This one rated for 5000 psi?
Question by: Ross W on Sep 6, 2025, 9:59 PM
350 bar which works out to 5000 psi is exactly what this valve is rated for. It's a poppet-style unit, so it holds up well under that kind of pressure without a lot of fuss. Built for heavy mobile equipment like refuse haulers, so that type of demanding, high-pressure work is right in its wheelhouse.
Answer by: Customer Support on Sep 8, 2025, 8:24 PM
Reckon this check valve would hold up okay on a refuse hauler, dealing with all that hydraulic pressure all day long?
Question by: Brent S on Aug 18, 2025, 8:52 AM
Designed for demanding environments, the Vickers CV11-10-P-0-55 is indeed suitable for applications like refuse haulers, operating efficiently up to 350 bar (5000 psi).
Answer by: Customer Support on Aug 19, 2025, 8:03 PM