VICKERS-PFR2-10-S-3G-/6.00

Application
harvesters, refuse haulers, mobile and industrial applications
Brand
Danfoss – Hydraulics
Brand
Vickers
Pack Size
1.00
UOM
EA
Features
350 bar (5000 psi) & 350 L/min (92 USgpm)|Perfect balance of pressure and flow|Reliable, economical and compact
Flow Rate1
60 litre per minute
ICC
SICV Flow Control Valves
Language
English
Port Size
3/8"
Product Width
2
Style
Adjustable Pressure Compensated, Flow Regulator
Sub Brand
Vickers
Supplier Part Number
02-199524
Product Weight
2.19 lbs

Product Questions & Answers

Wondering what kind of machines this flow regulator is typically used on?
Question by: Jimmy E on Jan 28, 2026, 5:47 PM
This Vickers PFR2-10 flow control valve is designed for use in mobile and industrial applications, such as harvesters and refuse haulers.
Answer by: Customer Support on Jan 30, 2026, 8:22 AM
Running this on a refuse hauler that sees a lot of load swings throughout the day. Will the flow stay consistent even when the system pressure bounces around?
Question by: Rusty E on Oct 15, 2025, 9:25 PM
Pressure-compensated flow regulators handle exactly that situation. The PFR2-10-S-3G-/6.00 maintains a steady output flow regardless of inlet or outlet pressure changes, so load swings on a refuse hauler won't cause the flow to drift. That consistent output is the whole point of pressure compensation, and it's one of the main reasons this valve gets spec'd on mobile equipment where load conditions are always shifting.
Answer by: Customer Support on Oct 17, 2025, 10:53 AM