VICKERS PRV2-10-S-0-35/27

Application
Harvesters, refuse haulers, mobile and industrial applications
Brand
Danfoss – Hydraulics
Brand
Vickers
Pack Size
1.00
UOM
EA
Features
350 bar (5000 psi) & 300 L/min (80 USgpm)|Reliable, economical and compact|Maximum flexibility and minimum space
Flow Rate1
38 litre per minute
ICC
SICV Pressure Control Valves
Language
English
Net Pack Quantity Units
EA
Port Size
None
Product Width
1
Style
Spool
Sub Brand
Vickers
Supplier Part Number
02-199317
Product Weight
0.54 lbs

Product Questions & Answers

Running this on a refuse hauler that works pretty hard most days. That 38 L/min flow rating listed, is that the continuous operating flow or just the max the valve can handle before you start seeing trouble?
Question by: Duane H on Feb 27, 2026, 3:17 PM
The 38 liters per minute figure is the rated flow rate for this valve under normal operating conditions. Separate from that, the PRV2-10-S-0-35/27 carries a maximum flow capacity of 300 L/min (80 USgpm), which represents the upper ceiling the valve can physically handle. On a refuse hauler running hard daily cycles, you have solid headroom between that rated flow and the max capacity, so the valve is well suited to that kind of demanding, continuous-duty environment.
Answer by: Customer Support on Feb 28, 2026, 4:22 PM