Flow rate on this one says 23 liters per minute but then somewhere else it mentions 265 L/min -- which number actually applies to my system?
Question by: Billy K on Nov 20, 2025, 11:19 AM
Both numbers are real, they just refer to different things. The 23 liters per minute is the rated control flow through the valve under standard operating conditions. The 265 L/min figure is the maximum flow capacity the valve can physically handle. So if your system runs closer to that upper range, the valve won't choke, but the 23 L/min is what it's optimized to regulate at. For most harvest equipment and refuse hauler setups, that rated flow is right in the working range you'd expect.
Answer by: Customer Support on Nov 22, 2025, 6:10 AM