I'm looking at using this on a refuse hauler. Is it tough enough to handle that kinda work?
Question by: Dale M on Sep 6, 2025, 9:36 PM
Specifically designed for mobile and industrial applications like harvesters and refuse haulers, this Vickers flow control valve should hold up well in that environment.
Answer by: Customer Support on Sep 8, 2025, 12:53 PM
Running this on a refuse hauler and need to know if it'll hold up pressure-wise. What's the max this valve can handle?
Question by: Kirk K on Sep 16, 2025, 11:09 AM
At 350 bar (5000 psi), it's built for exactly the kind of demanding cycles you'd see on refuse haulers. The flow tops out at 38 liters per minute on this particular model, and the pressure-compensated design keeps things steady even when load conditions shift. It's been called out specifically for refuse hauler use, so you're in the right territory.
Answer by: Customer Support on Sep 17, 2025, 6:26 PM