Product Questions & Answers

got a refuse hauler that needs steady flow even when load pressure swings around a good bit, this the kind of valve that handles that?
Question by: Dale B on Feb 3, 2026, 5:48 PM
Pressure-compensated valves are built exactly for that situation. The FAR1 12 H 0 holds a consistent flow rate regardless of load variation, so you're not chasing adjustments every time conditions shift on the truck. It's rated to 350 bar and handles up to 350 L/min, which gives you plenty of headroom for a refuse hauler application. The free reverse flow path is also already built in, so you don't need extra components to handle bidirectional flow in the circuit.
Answer by: Customer Support on Feb 5, 2026, 6:34 AM