VICKERS RV5-16-C-0-30/18

Application
Harvesters, refuse haulers, mobile and industrial applications
Brand
Danfoss – Hydraulics
Brand
Vickers
Pack Size
1.00
UOM
EA
Features
350 bar (5000 psi) & 300 L/min (80 USgpm)|Reliable, economical and compact|Maximum flexibility and minimum space
Flow Rate1
300 litre per minute
ICC
SICV Pressure Control Valves
Language
English
Port Size
None
Product Width
1.50
Style
Spool
Sub Brand
Vickers
Supplier Part Number
02-182529
Product Weight
1.57 lbs

Product Questions & Answers

Running this on a refuse hauler setup. What kind of pressure and flow can I expect out of it?
Question by: Rex R on Sep 23, 2025, 7:53 PM
Rated at 350 bar (5000 psi) maximum pressure with a flow capacity of 300 liters per minute, which works out to about 80 US gallons per minute. That's a solid range for heavy-duty mobile equipment like refuse haulers, and it lines up well with the kind of demand those systems typically put on a pressure control valve.
Answer by: Customer Support on Sep 25, 2025, 7:40 AM
Will this here valve work on my harvester? I need one that can handle some pressure.
Question by: Lyle O on Jun 21, 2025, 12:34 PM
Rated to a maximum pressure of 350 bar (5000 psi) and a flow rate of 300 liters per minute (80 USgpm), the RV5-16-C-0-30/18 pressure control valve is designed for mobile and industrial applications like harvesters.
Answer by: Customer Support on Jun 23, 2025, 6:01 AM