VICKERS PFR1-16-F-12T-/8.00

Application
harvesters, refuse haulers, mobile and industrial applications
Brand
Danfoss – Hydraulics
Brand
Vickers
Pack Size
1.00
UOM
EA
Features
350 bar (5000 psi) & 350 L/min (92 USgpm)|Perfect balance of pressure and flow|Reliable, economical and compact
Flow Rate1
151 litre per minute
ICC
SICV Flow Control Valves
Language
English
Port Size
3/4"
Product Width
2
Style
Fixed Pressure Compensated, Flow Regulator
Sub Brand
Vickers
Supplier Part Number
02-181547
Product Weight
3.14 lbs

Product Questions & Answers

Flow rate on this one says 151 liters per minute but the max listed is 350 L/min at 92 gpm. which number actually applies to my setup?
Question by: Ralph M on Nov 2, 2025, 8:09 AM
Fixed pressure compensated regulators like this one operate with two different flow figures worth knowing. The 151 liters per minute is the regulated output flow this valve is built to maintain consistently. The 350 L/min at 92 USgpm reflects the maximum system capacity it can handle passing through. So if your circuit needs steady, controlled flow rather than full throughput, the 151 L/min is the number that matters for your application sizing.
Answer by: Customer Support on Nov 4, 2025, 6:31 AM