VICKERS FDC1-20-0-88

Application
Harvesters, refuse haulers, mobile and industrial applications
Brand
Danfoss – Hydraulics
Brand
Vickers
Pack Size
1.00
UOM
EA
Features
350 bar (5000 psi) & 350 L/min (92 USgpm)|Perfect balance of pressure and flow|Reliable, economical and compact
Flow Rate1
141 litre per minute
ICC
SICV Flow Control Valves
Language
English
Product Width
2.50
Style
Spool
Sub Brand
Vickers
Supplier Part Number
02-177422
Product Weight
5.75 lbs

Product Questions & Answers

Running this on a refuse hauler that works pretty hard most days. What's the flow and pressure this valve can actually handle before you're pushing it too far?
Question by: Billy E on Sep 5, 2025, 9:08 PM
At max, you're looking at 350 bar (5000 psi) of pressure and up to 350 liters per minute (92 US gallons per minute) of flow. For typical day-to-day operation on a hauler, the expected working flow rate runs around 141 liters per minute. So there's solid headroom above that typical rate, which means a hard-working refuse application sits comfortably within what this valve is built for.
Answer by: Customer Support on Sep 7, 2025, 6:44 AM