VICKERS PFR1 16 F 0 7.00

Application
Harvesters, refuse haulers, mobile and industrial applications
Brand
Danfoss – Hydraulics
Brand
Vickers
Pack Size
1.00
UOM
EA
Features
350 bar (5000 psi) & 350 L/min (92 USgpm)|Perfect balance of pressure and flow|Reliable, economical and compact
Flow Rate1
151 litre per minute
ICC
SICV Flow Control Valves
Language
English
Product Width
1.50
Special Features
None
Style
Fixed Pressure Compensated, Flow Regulator
Sub Brand
Vickers
Supplier Part Number
02-176388
Product Weight
0.84 lbs

Product Questions & Answers

Running a refuse hauler and need a flow control that won't quit on me, does this Vickers unit hold up to that kind of work?
Question by: Lance R on Dec 24, 2025, 2:27 PM
Refuse hauler duty is actually one of the applications this valve was built around, along with harvester equipment and other mobile setups that put a lot of stress on hydraulic components. It runs up to 350 bar (5000 psi) and handles flow up to 151 liters per minute, so it has the pressure and flow capacity to keep pace with demanding cycles. The fixed pressure compensated design keeps things regulated consistently, which matters a lot when your system loads are always shifting around.
Answer by: Customer Support on Dec 26, 2025, 6:51 AM