VICKERS-VF1-16V-F-0-/30.00

Application
Harvesters, refuse haulers, mobile and industrial applications
Brand
Danfoss – Hydraulics
Brand
Vickers
Pack Size
1.00
UOM
EA
Features
350 bar (5000 psi) & 350 L/min (92 USgpm)|Perfect balance of pressure and flow|Reliable, economical and compact
Flow Rate1
114 litre per minute
ICC
SICV Flow Control Valves
Language
English
Product Width
1.50
Sub Brand
Vickers
Supplier Part Number
02-176347
Product Weight
0.72 lbs

Product Questions & Answers

Running this on a refuse hauler that works hard every day. Flow needs are around 100 litres per minute. That gonna be within range for this valve?
Question by: Dean B on May 24, 2025, 11:50 AM
At 114 litres per minute max flow, you've got a little headroom above your 100 LPM requirement, which is right where you want to be for a working machine that sees daily duty cycles. Refuse haulers are actually one of the named applications for this valve series, so it fits that kind of environment without being oversized or undersized for the job.
Answer by: Customer Support on May 26, 2025, 6:15 AM