Product Questions & Answers

Got a refuse hauler that's been running hot and inconsistent on flow, would a fixed pressure-compensated valve like this one help steady things out?
Question by: Dwayne W on Jan 11, 2026, 3:04 PM
Fixed pressure-compensated valves are built specifically for that kind of problem. When system pressure fluctuates, an uncompensated valve lets flow vary right along with it, which causes erratic actuator speeds and added heat load. The FR1-20 holds flow steady regardless of pressure changes upstream or downstream, so your circuit stays consistent even when demand shifts. At 227 liters per minute flow rate and a 350 bar pressure rating, it has plenty of headroom for most refuse hauler hydraulic circuits.
Answer by: Customer Support on Jan 13, 2026, 1:58 PM
Reckon this would hold up on a rig running near full tilt all day long?
Question by: Pete H on Jun 13, 2025, 7:33 AM
This Vickers flow control valve handles up to 350 bar (5000 psi) and 350 L/min (92 USgpm), so it should do the job, assuming your system doesn't exceed those levels.
Answer by: Customer Support on Jun 15, 2025, 8:51 AM