Product Questions & Answers

Wondering what kind of machines this valve typically gets used on?
Question by: Tammy R on Dec 25, 2025, 4:32 PM
This pressure control valve is often found on harvesters and refuse trucks, but it's also suitable for a wide variety of mobile and industrial hydraulic applications.
Answer by: Customer Support on Dec 27, 2025, 11:02 AM
got a refuse hauler that needs a new pressure control valve, the old one was running around 5000 psi max. this PRV2 10 C 0 35/30 gonna hold up to that?
Question by: Jimmy J on Mar 19, 2026, 10:59 AM
350 bar works out to right at 5000 psi, so you're looking at a direct match on the pressure rating. The PRV2 10 C 0 35/30 is built for exactly that kind of work, refuse haulers are actually listed as one of its target applications. Flow capacity tops out at 300 liters per minute, which is 80 USgpm, so it's got plenty of headroom for a typical refuse truck hydraulic circuit. Compact build too, which helps when you're working around tight mounting situations on that kind of equipment.
Answer by: Customer Support on Mar 21, 2026, 7:14 AM