Product Questions & Answers

reckon this would work on a refuse hauler?
Question by: Connie M on May 28, 2025, 1:02 PM
Application-wise, this Vickers CV3-8 series check valve is indeed suitable for refuse haulers, as well as harvesters and other mobile and industrial applications.
Answer by: Customer Support on May 30, 2025, 7:49 AM
Got a harvester that keeps seeing pressure spikes up around 4800 psi. will this check valve hold up at them levels without bleedin' through?
Question by: Bobby S on Nov 26, 2025, 6:20 PM
At 4800 psi you'd still have some headroom under the 5000 psi rated ceiling on this valve. The poppet style sealing is what gives it the edge in high-pressure situations like that. Poppet designs hold a tighter seal under load compared to ball-type valves, so pressure spikes in that range shouldn't cause bypass issues. It's a solid fit for harvesting equipment specifically, which is one of the listed applications for this valve.
Answer by: Customer Support on Nov 28, 2025, 7:54 AM