VICKERS FR2-10-K-0-/0.70

Application
harvesters, refuse haulers, mobile and industrial applications
Brand
Danfoss – Hydraulics
Brand
Vickers
Pack Size
1.00
UOM
EA
Features
350 bar (5000 psi) & 350 L/min (92 USgpm)|Perfect balance of pressure and flow|Reliable, economical and compact
Flow Rate1
38 litre per minute
ICC
SICV Flow Control Valves
Language
English
Product Width
1
Style
Adjustable Pressure Compensated, Flow Regulator
Sub Brand
Vickers
Supplier Part Number
02-173407
Product Weight
0.48 lbs

Product Questions & Answers

flow rate on this one says 38 litres per minute but the max listed is 350 L/min -- which one actually applies to how it runs day to day on something like a refuse hauler?
Question by: Jimmy H on Jan 19, 2026, 1:19 PM
The 38 litres per minute is the working flow rate for this valve, meaning that's what it's set to regulate under normal operating conditions. The 350 L/min figure is the maximum capacity the valve can handle, not the rate it controls to. On a refuse hauler or similar mobile equipment, you'd be running at or around that 38 L/min regulated output, while the system itself could have higher flow passing through other circuits. The valve keeps things balanced at that controlled rate even as pressure fluctuates, which is the whole point of a pressure-compensated design.
Answer by: Customer Support on Jan 21, 2026, 6:44 AM