Product Questions & Answers

So this thing will keep the flow at 10 liters per minute even if the pressure changes, right?
Question by: Freddie W on Dec 4, 2025, 7:16 PM
That's correct. This fixed pressure compensated flow regulator is designed to maintain a consistent 10 liters per minute output, regardless of pressure fluctuations in the system, up to its maximum rating of 350 bar (5,000 psi).
Answer by: Customer Support on Dec 6, 2025, 6:55 AM
Got a harvester that keeps losing consistent flow anytime the load pressure changes up, would this Vickers unit hold a steady 10 litres per minute regardless of what's going on downstream?
Question by: Roy J on Mar 9, 2026, 7:17 AM
Pressure-compensated flow regulators like this one are built specifically for that situation. The PFR5-8-F-0-0.10 holds a fixed output of 10 litres per minute and actively compensates for load-induced pressure variation, so fluctuations downstream won't throw off your regulated flow. It's rated up to 350 bar (5,000 psi) with a system flow capacity of 350 L/min, which gives it plenty of headroom for demanding harvester circuits.
Answer by: Customer Support on Mar 11, 2026, 8:51 AM