VICKERS FDC1 16 0 84

Application
Harvesters, refuse haulers, mobile and industrial applications
Brand
Danfoss – Hydraulics
Brand
Vickers
Pack Size
1.00
UOM
EA
Features
350 bar (5000 psi) & 350 L/min (92 USgpm)|Perfect balance of pressure and flow|Reliable, economical and compact
Flow Rate1
178 litre per minute
ICC
SICV Flow Control Valves
Language
English
Product Width
1.50
Style
Spool
Sub Brand
Vickers
Supplier Part Number
02-163428
Product Weight
0.78 lbs

Product Questions & Answers

Flow rate on this thing goes up to 178 liters per minute, but the max listed is 350 L/min. What's the difference there, and which one applies to how this valve actually runs day to day?
Question by: Todd R on Jun 26, 2025, 6:58 PM
Running conditions matter a lot with this one. The 178 liters per minute is the controlled flow rate for normal operating conditions, which is what you'd plan around for your actual system work. The 350 L/min figure is the maximum the valve can handle passing through it overall. So day to day, size your system around the 178 L/min controlled rate, and know the valve won't be a bottleneck if you've got higher total flow moving through the circuit.
Answer by: Customer Support on Jun 28, 2025, 11:28 AM