Product Questions & Answers

Reckon this flow regulator would hold up okay on a harvester?
Question by: Diane J on Sep 28, 2025, 9:48 PM
It's designed for applications just like that, including use in harvesters and refuse haulers, so it should be a good fit. This Vickers flow control valve offers a reliable, economical, and compact solution.
Answer by: Customer Support on Sep 30, 2025, 6:20 AM
flow rate on this valve is listed at 60 L/min but the specs also mention 350 L/min -- which one actually applies to this unit?
Question by: Ronnie S on Jun 27, 2025, 10:08 AM
Good catch on that. The 60 liters per minute figure is the flow rate for this specific valve, the PFR2-10-C-0-/2.50. The 350 L/min and 350 bar ratings reflect the broader capability ceiling of the PFR2-10 series, not what this particular unit is sized to flow. So for your sizing and circuit planning, work off the 60 L/min number for actual throughput.
Answer by: Customer Support on Jun 29, 2025, 6:49 AM