VICKERS PFR2-10-C-0-/0.50

Application
Harvesters, refuse haulers, mobile and industrial applications
Brand
Danfoss – Hydraulics
Brand
Vickers
Pack Size
1.00
UOM
EA
Features
350 bar (5000 psi) & 350 L/min (92 USgpm)|Perfect balance of pressure and flow|Reliable, economical and compact
Flow Rate1
60 litre per minute
ICC
SICV Flow Control Valves
Language
English
Net Pack Quantity Units
EA
Product Width
1
Style
Adjustable Pressure Compensated, Flow Regulator
Sub Brand
Vickers
Supplier Part Number
02-112877
Product Weight
0.54 lbs

Product Questions & Answers

got a harvester that needs steady flow even when the load changes, is this valve the right kind for that?
Question by: Hugh T on May 3, 2025, 9:14 AM
Pressure compensated flow regulation is what this unit is built for, so it is meant to hold a set flow rate even as system pressure varies. It is an adjustable flow regulator used in mobile and industrial equipment like harvesters and refuse haulers.
Answer by: Customer Support on May 4, 2025, 9:59 AM
flow rate on this thing tops out at 60 liters per minute, but the specs also mention 350 L/min somewhere -- how do them two numbers fit together?
Question by: Cody S on Aug 15, 2025, 7:52 PM
Good catch, and it's worth clearing up. The 350 L/min figure refers to the maximum flow capacity the valve itself can handle passing through it under rated conditions. The 60 liters per minute is the regulated output -- meaning that's the controlled flow this unit is set to deliver after compensation. So the valve can physically handle a lot more fluid moving through the system, but it's holding the working output steady at 60 L/min. That's exactly what a pressure compensated flow regulator does: it keeps your output flow consistent regardless of load changes or pressure swings upstream.
Answer by: Customer Support on Aug 16, 2025, 8:46 PM