flow rate on this one says 80 litres per minute -- is that enough for a standard press circuit or would it be cutting it close?
Question by: Cody R on Sep 19, 2025, 4:12 PM
For most press applications, 80 litres per minute gives you solid headroom. Press circuits tend to run lower flow demands during the actual control function, so this valve fits right in without being a bottleneck. The DG4V series was built with press use as one of its primary applications, so you're not working against the design here.
Answer by: Customer Support on Sep 21, 2025, 6:04 AM
got a valve on the shelf tagged DG4V36CMFTWLB660. is that the same thing as SKU 02-110359 or am i mixin stuff up
Question by: Kent W on Mar 22, 2026, 8:49 PM
For cross reference, SKU 02-110359 is shown with the alternate part number DG4V36CMFTWLB660. Those two identifiers point to the same valve.
Answer by: Customer Support on Mar 24, 2026, 2:23 PM
What kind of fluid seals does this valve use?
Question by: Hubert S on Mar 26, 2026, 3:48 PM
This valve uses Viton seals to ensure reliable fluid compatibility across various hydraulic applications.
Answer by: Customer Support on Mar 28, 2026, 6:50 AM